LOSS OF POWER TO SAFETY CIRCUITS
The hydraulic drives that operate the “scram” mechanism require reserve pressure to keep them in the “ready” position for “scram” condition and are an integral part of the safety circuitry. A power failure in the safety circuits would automatically put the hydraulic drives into operation to “scram” the reactor.