EXPERIMENTAL TECHNIQUE
In almost all experiments, the basic signal-energy mechanism employed has been essentially that one studied most extensively by [Lillie (12)], [Bonhoeffer (2)], [Yamagiwa (22)], [Matumoto and Goto (14)] and others, i.e., activation, impulse propagation and recovery on the normally passive surface of a piece of iron immersed in nitric acid or of cobalt in chromic acid [(20)]. The iron we have used most frequently is of about 99.99% purity, which gives performance more consistent than but similar to that obtained using cleaned “coat-hanger” wires. The acid used most frequently by us is about 53-55% aqueous solution by weight, substantially more dilute than that predominantly used by previous investigators. The most frequently reported concentration has been 68-70%, a solution which is quite stable and, hence, much easier to work with in open containers than the weaker solutions, results in very fast waves but gives, at room temperatures, a very long refractory period (typically, 15 minutes). A noble metal (such as silver, gold or platinum) placed in contact with the surface of the iron has a stabilizing effect [(14)] presumably through the action of local currents and provides a simple and useful technique whereby, with dilution, both stability and fast recovery (1 second) can be achieved in simple demonstrations and experiments.
Experiments involving the growth by electrodeposition and study of metallic dendrites are done with an eye toward electrical, physical and chemical compatibility with the energy-producing system outlined above. Best results to date (from the standpoints of stability, non-reactivity, and morphological similarity to neurological structures) have been obtained by dissolving various amounts of gold chloride salt in 53-55% HNO₃.
An apparatus has been devised and assembled for the purpose of containing and controlling our primary experiments. ([See Figure 1]). Its two major components are a test chamber (on the left in [Figure 1]) and a fluid exchanger (on the right). In normal operation the test chamber, which is very rigid and well sealed after placing the experimental assembly inside, is completely filled with electrolyte (or, initially, an inert fluid) to the exclusion of all air pockets and bubbles. Thus encapsulated, it is possible to perform experiments which would otherwise be impossible due to instability. The instability which plagues such experiments is manifested in copious generation of bubbles on and subsequent rapid disintegration of all “excitable” material (i.e., iron). Preliminary experiments indicated that such “bubble instability” could be suppressed by constraining the volume available to expansion. In particular, response and recovery times can now be decreased substantially and work can proceed with complex systems of interest such as aggregates containing many small iron pellets.
The test chamber is provided with a heater (and thermostatic control) which makes possible electrochemical impulse response and recovery times comparable to those of the nervous system (1 to 10 msec). The fluid-exchanger is so arranged that fluid in the test chamber can be arbitrarily changed or renewed by exchange within a rigid, sealed, completely liquid-filled (“isochoric”) loop. Thus, stability can be maintained for long periods of time and over a wide variety of investigative or operating conditions.
Most of the parts of this apparatus are made of stainless steel and are sealed with polyethylene and teflon. There is a small quartz observation window on the test chamber, two small lighting ports, a pressure transducer, thermocouple, screw-and-piston pressure actuator and umbilical connector for experimental electrical inputs and outputs.