BOILER TUBES.

The following table gives the draught area and heating surface of the various sized boiler tubes and flues:

External
Diameter.
Draught area
in sq. inches.
Draught Area
in sq. feet.
Heating surface
in feet per ft. of
tube in length.
No. of tubes
in 1 sq. foot of
draught area.
5/8.............1636.....
¾.............1963.....
1.575.0040.2618250.0
.968.0067.3272149.3
1.389.00964.3927103.7
1.911.0133.458175.2
22.573.0179.523655.9
3.333.0231.589143.3
4.083.0284.654535.2
5.027.0349.720028.7
36.070.0422.785423.7
7.116.0494.850820.2
8.347.0580.916317.2
9.676.0672.981814.9
410.93.07591.047213.2
14.05.09961.178110.2
517.35.12051.30908.3
625.25.17531.57085.7
734.94.24261.83264.1
846.20.32082.09443.1
958.63.40722.35622.5
1072.23.50162.61802.0