The numbers in the column headed "Value of one turn of the screw" were taken from the table, page 127.

Date. Distinctness of image. Temperature, Fahr. Position of deflected image. Position of slit. Displacement of image in divisions. Difference between greatest and least values. B. Cor. Number of revolutions per second. Radius of measurement, in feet. Value of one turn of the screw. Velocity of light in air, in kilometers. Remarks.
June 5376114.85 0.300114.550.171.423-0.132257.3628.6720.99614299850Electric light.
June 7272114.64 0.074114.560.101.533-0.084257.5228.6550.99614299740P.M. Frame inclined at various angles
June 7272114.58 0.074114.500.081.533-0.084257.5228.6470.99614299900P.M. Frame inclined at various angles
June 7272 85.91 0.074 85.840.121.533-0.084193.1428.6470.99598300070P.M. Frame inclined at various angles
June 7272 85.97 0.074 85.89O.071.533-0.084193.1428.6500.99598299930P.M. Frame inclined at various angles
June 7272114.61 0.074114-530.071.533-0.084257.4228.6500.99614299850P.M. Frame inclined at various angles
June 9383114.54 0.074114.470.071.533-0.216257.3928.6580.99614299950P.M. Frame inclined at various angles
June 9383114.54 0.074114.460.101.533-0.216257.3928.6580.99614299980P.M. Frame inclined at various angles
June 9383114.57 0.074114.470.081.533-0.216257.3928.6620.99614299980P.M. Frame inclined at various angles
June 9383114.57 0.074114.500.061.533-0.216257.3928.6600.99614299880P.M. Frame inclined at various angles
June 9283114.61 0.074114.530.131.533-0.216257.3928.6780.99614300000P.M. Frame inclined at various angles
June 10290114.60 0.074114.520.111.517-0.300257.2928.6850.99614299980P.M.
June 10290114.62 0.074114.540.081.517-0.300257.2928.6850.99614299930P.M.
June 12271114.81 0.074114.740.091.450-0.072257.4528.6900.99614299650A.M.
June 12271114.78 0.074114.700.051.450-0.072257.4528.6900.99614299760A.M.
June 12171114.76 0.074114.680.091.450-0.072257.4528.6900.99614299810A.M.
June 13372112.64 0.074112.560.091.500-0.084257.4928.1720.99614300000A.M.
June 13372112.63 0.074112.560.101.500-0.084257.4928.1720.99614300000A.M.
June 13272112.65 0.074112.570.081.500-0.084257.4928.1720.99614299960A.M.
June 13379112.82 0.260112.560.061.517-0.168257.4228.1780.99614299960P.M.
June 13379112.82 0.260112.560.131.517-0.168257.4228.1780.99614299960P.M.
June 13379112.83 0.260112.570.071.517-0.168257.4228.1780.99614299940P.M.
June 13379112.82 0.260112.560.061.517-0.168257.4228.1780.99614299960P.M.
June 13379112.83 0.260112.570.111.517-0.168257.4228.1780.99614299940P.M.
June 13379113.41 0.260113.1511 1.517-0.168258.7028.1520.99614299880P.M. Set micrometer and counted oscillations.
June 13379112.14 0.260111.886 1.517-0.168255.6928.1520.99614299800Oscillations of image of revolving mirror.
June 14164112.83 0.260112.570.121.500+0.012257.5828.1520.99614299850A.M.
June 14164112.83 0.260112.570.051.517+0.012257.6028.1520.99614299880A.M.
June 14165112.81 0.260112.550.111.517 0.000257.5928.1520.99614299900A.M.
June 14166112.83 0.260112.570.091.517-0.012257.5728.1520.99614299840A.M.
June 14167112.83 0.260112.570.121.517-0.024257.5628.1520.99614299830A.M.
June 14184112.78 0.260112.520.061.517-0.228257.3628.1590.99614299790P.M. Readings taken by Lieut. Nazro.
June 14185112.76 0.260112.500.081.500-0.240257.3328.1590.99614299810P.M. Readings taken by Lieut. Nazro.
June 14184112.72 0.260112.460.081.483-0.228257.3228.1590.99614299880P.M. Readings taken by Lieut. Nazro.
June 14184112.73 0.260112.470.091.483-0.228257.3228.1590.99614299880P.M.
June 14184112.75 0.260112.490.091.483-0.228257.3228.1290.99614299830P.M.
June 17262112.85 0.260112.590.091.517+0.036257.6228.1490.99614299800A.M.
June 17263112.84 0.260112.580.061.500+0.024257.5928.1490.99614299790A.M.
June 17164112.85 0.260112.590.071.500+0.012257.5828.1490.99614299760A.M.
June 17377112.80 0.260112.540.071.500-0.144257-4328.1570.99614299800P.M. Readings taken by Mr. Clason.
June 17377112.77 0.260112.510.081.500-0.144257.4328.1570.99614299880P.M. Readings taken by Mr. Clason.
June 17377112.77 0.260112.510.111.500-0.144257.4328.1570.99614299880P.M. Readings taken by Mr. Clason.
June 17377112.77 0.260112.510.091.500-0.144257.4328.1570.99614299880P.M. Readings taken by Mr. Clason.
June 17377112.78 0.260112.520.081.500-0.144257 4328.1570.99614299860P.M. Readings taken by Mr. Clason.
June 18158112.90 0.265112.640.071.500+0.084257.6528.1500.99614299720A.M.
June 18158112.90 0.265112.640.101.500+0.084257.6528.1500.99614299720A.M.
June 18159112.92 0.265112.660.071.483+0.072257.6228.1500.99614299620A.M.
June 18275112.79 0.265112.520.091.483-0.120257-4328.1580.99614299860P.M.
June 18275112.75 0.265112.480.101.483-0.120257-4328.1580.99614299970P.M.
June 18275112.76 0.265112.490.081.483-0.120257-4328.1580.99614299950P.M.
June 20360112.94 0.265112.670.071.517+0.063257.6528.1720.99614299880A.M.
June 20361112.92 0.265112.650.091.517+0.048257.6328.1720.99614299910A.M.
June 20262112.94 0.265112.670.071.517+0.036257.6228.1720.99614299850A.M.
June 20263112.93 0.265112.660.031.517+0.024257.6128.1720.99614299870A.M.
June 20278133.48 0.265133.210.131.450-0.156257.3633.3450.99627299840P.M.
June 20279133.49 0.265133.230.091.500-0.168257.4033.3450.99627299840P.M.
June 20280133.49 0.265133.220.071.500-0.180257.3933.3450.99627299850P.M.
June 20279133.50 0.265133.240.131.483-0.168257.3933.3450.99627299840P.M.
June 20279133.49 0.265133.220.061.483-0.168257.3833.3450.99627299840P.M.
June 20279133.49 0.265133.220.101.483-0.168257.3833.3450.99627299840P.M.
June 21261133.56 0.265133.290.121.533+0.048257.6533.3320.99627299890A.M.
June 21262133.58 0.265133.310.081.533+0.036257.6433.3320.99627299810A.M.
June 21263133.57 0.265133.310.091.533+0.024257.6333.3320.99627299810A.M.
June 21264133.57 0.265133.300.111.533+0.012257.6133.3320.99627299820A.M.
June 21265133.56 0.265133.300.131.533 0.000257.6033.3320.99627299800A.M.
June 21380133.48 0.265133.210.061.533-0.180257.4233.3300.99627299770P.M.
June 21381133.46 0.265133.190.101.500-0.192257.3833.3300.99627299760P.M.
June 21382133.46 0.265133.200.051.500-0.204257.3733.3300.99627299740P.M.
June 21382133.46 0.265133.200.081.517-0.204257.3833.3300.99627299750P.M.
June 21381133.46 0.265133.190.081.500-0.192257.3833.3300.99627299760P.M.
June 23389133.43 0.265133.160.081.542-0.288257.3233.3450.99627299910P.M.
June 23389133.42 0.265133.150.061.550-0.288257.3333.3450.99627299920P.M.
June 23390133.43 0.265133.170.091.550-0.300257.3233.3450.99627299890P.M.
June 23390133.43 0.265133.160.071.533-0.300257.3033.3450.99627299860P.M.
June 23390133.42 0.265133.160.071.517-0.300257.2933.3450.99627299880P.M.
June 24372133.47 0.265133.200.151.517-0.084257.5033.3190.99627299720A.M.
June 24373133.44 0.265133.170.041.517-0.096257.4933.3190.99627299840A.M.
June 24374133.42 0.265133.160.111.517-0.108257.4833.3190.99627299850A.M.
June 24375133.42 0.265133.160.061.517-0.120257.4733.3190.99627299850A.M.
June 24376133.44 0.265133.180.101.517-0.132257.4533.3190.99627299780A.M.
June 26286133.42 0.265133.150.051.508-0.252257.3333.3390.99627299890P.M.
June 26286133.44 0.265133.170.081.508-0.252257.3333.3390.99627299840P.M.
June 27373133.49 0.265133.220.111.483-0.096257.4633.3280.99627299780A.M.
June 27374133.47 0.265133.200.061.483-0.108257.4433.3280.99627299810A.M.
June 27375133.47 0.265133.210.091.483-0.120257.4333.3280.99627299760A.M.
June 27375133.45 0.265133.190.091.467-0.120257.4233.3280.99627299810A.M.
June 27376133.47 0.265133.200.081.483-0.132257.4233.3280.99627299790A.M.
June 27376133.45 0.265133.190.101.483-0.132257.4233.3280.99627299810A.M.
June 30285 35.32135.00 99.680.051.500-0.240193.0033.2740.99645299820P.M. Mirror inverted.
June 30286 35.34135.00 99.670.061.508-0.252193.0033.2740.99645299850P.M. Mirror inverted.
June 30286 35.34135.00 99.660.101.508-0.252193.0033.2740.99645299870P.M. Mirror inverted.
June 30286 35.34135.00 99.660.091.517-0.252193.0033.2740.99645299870P.M. Mirror inverted.
July 1283 02.17135.145132.980.071.500-0.216257.3533.2820.99627299810P.M. Mirror inverted.
July 1284 02.15135.145133.000.091.500-0.228257.3433.2820.99627299740P.M. Mirror inverted.
July 1286 02.14135.145133.010.061.467-0.252257.2833.3110.99627299810P.M. Mirror inverted.
July 1286 02.14135.145133.000.081.467-0.252257.2833.3110.99627299940P.M. Mirror inverted.
July 2386 99.85 0.400 99.450.051.450-0.252192.9533.2050.99606299950P.M. Mirror erect.
July 2386 66.74 0.400 66.340.031.450-0.252128.6333.2050.99586299800P.M. Mirror erect.
July 2386 50.16 0.400 47.960.071.467-0.252 96.4833.2050.99580299810P.M. Mirror erect.
July 2385 33.57 0.400 33.170.061.450-0.240 64.3233.2050.99574299870P.M. Mirror erect.

In the last two sets of June 13, the micrometer was fixed at 113.41 and 112.14 respectively. The image was bisected by the cross-hair, and kept as nearly as possible in this place, meantime counting the number of seconds required for the image of the revolving mirror to complete 60 oscillations. In other words, instead of measuring the deflection, the speed of rotation was measured. In column 7 for these two sets, the numbers 11 and 6 are the differences between the greatest and the smallest number of seconds observed.

In finding the mean value of V from the table, the sets are all given the same weight. The difference between the result thus obtained and that from any system of weights is small, and may be neglected.

The following table gives the result of different groupings of sets of observations. Necessarily some of the groups include others:

Electric light (1 set) 299850
Set micrometer counting oscillations (2) 299840
Readings taken by Lieutenant Nazro (3) 299830
Readings taken by Mr. Clason (5) 299860
Mirror inverted (8) 299840
Speed of rotation, 192 (7) 299990
Speed of rotation, 128 (1) 299800
Speed of rotation, 96 (1) 299810
Speed of rotation, 64 (1) 299870
Radius, 28.5 feet (54) 299870
Radius, 33.3 feet (46) 299830
Highest temperature, 90° Fahr. (5) 299910
Mean of lowest temperatures, 60° Fahr. (7) 299800
Image, good (46) 299860
Image, fair (39) 299860
Image, poor (15) 299810
Frame, inclined (5) 299960
Greatest value 300070
Least value 299650
Mean value 299852
Average difference from mean 60
Value found for π 3.26
Probable error ± 5

Discussion of Errors.

The value of V depends on three quantities D, n, and φ. These will now be considered in detail.

The Distance.

The distance between the two mirrors may be in error, either by an erroneous determination of the length of the steel tape used, or by a mistake in the measurement of the distance by the tape.