Offsite monitoring teams in areas northeast of ground zero encountered gamma readings ranging from 1.5 to 15 R/h two to four hours after the detonation. Three hours after the detonation, surveys taken in Bingham, New Mexico (located 30 kilometers northeast of ground zero) found gamma intensities of about 1.5 R/h. Radiation readings at the town of White, nine kilometers southeast of Bingham, were 6.5 R/h three hours after the detonation and 2.5 R/h two hours later. Another team monitoring in a canyon 11 kilometers east of Bingham found a gamma intensity of about 15 R/h. Five hours later, the intensity had decreased to 3.8 R/h. It was estimated that peak intensities of gamma radiation from fallout on shot-day were about 7 R/h at an occupied ranch house in this canyon area (1; 11; 19).

Monitoring teams resurveyed these towns about one month after the TRINITY detonation. At Bingham, gamma readings of 0.003 R/h and 0.0001 R/h were found at ground level outdoors and at waist level inside a building, respectively. At the town of White, the highest outdoor gamma reading was 0.008 R/h. Inside a building, the highest reading was 0.0005 R/h (11).

Surveys taken in the canyon area one month after the detonation indicated that gamma intensities at ground level had decreased to 0.032 R/h. The occupied ranch house was also surveyed, both inside and outside. The highest reading outdoors was 0.028 R/h, and the highest reading indoors was 0.004 R/h (11; 19).

Monitoring was also conducted in offsite areas other than those to the north and northeast of ground zero. Monitors found no radiation readings above background levels (11).

Significant fallout from the TRINITY cloud did not reach the ground within about 20 kilometers northeast of ground zero. From this point, the fallout pattern extended out 160 kilometers and was 48 kilometers wide. Gamma intensities up to 15 R/h were measured in this region several hours after the detonation. One month later, intensities had declined to 0.032 R/h or less (11).

CHAPTER 4

DOSIMETRY ANALYSIS OF PARTICIPANTS IN PROJECT TRINITY

This chapter summarizes the radiation doses received by participants in various activities during Project TRINITY. The sources of this dosimetry information are the safety and monitoring report for personnel at TRINITY, which includes a compilation of film badge readings for all participants up to 1 January 1946, and film badge data from the records of the Reynolds Electrical and Engineering Company, which contain readings through 1946 (1; 16). These sources list individual participants with their cumulative gamma radiation exposures.

4.1 FILM BADGE RECORDS

During TRINITY, the film badge was the primary device used to measure the radiation dose received by individual participants. The site monitoring plan indicates that film badges were to be issued to participants. The film badge was normally worn at chest level on the outside of clothing and was designed to measure the wearer's exposure to gamma radiation from external sources. These film badges were insensitive to neutron radiation and did not measure the amount of radioactive material that might have been inhaled or ingested (1).