3. Keep the melted lead in the lead pot clean at all times.

4. Always completely fill each mould at one pouring.

5. Dust moulds well with Ambu mould compound before pouring.

6. When castings “shrink” and crack, add pure lead to that in the pot until the trouble is remedied.

7. Be sure melted lead is of proper temperature, by pine stick test, before starting to pour.

8. Remove castings as soon as they set, to prevent the mould from becoming too hot.

9. A perfect casting, that breaks when taken out of the mould, has probably not been allowed sufficient time to “set” or cool properly.

10. Never use a hammer on the surface of the mould. If a casting should stick, pry it out.

AMBU COMBINATION LINK MOULD

Using both sides, this mould casts five of the most used connectors for all batteries, using Standard Jars, 7-9-11-13-15 Plate four end connectors (two Dodge Tapers and two Standard Tapers, Negative and Positive), one end connector, ⅜-inch wire leed used on 12-volt Maxwell and other cars using wire leed. One small wire leed to connect with end post on storage battery requiring direct connection. Post support rings, which fit the two sizes standard rubber covers; also fit perfectly all posts cast with our post mould. Two handy washers that sometimes are badly needed when installing a new or rent battery.