No water to be added without the express permission of the architect.

(6) The boxes are to be filled in thin layers of not more than 4 in. at a time, and well rammed until solid. The workmen are not to use their rammers in unison.

Newlands. The Garden Court.

(7) Rammed earth at box ends to be shaved down to a 45 degrees slope so as to splice in with new span of pisé adjoining it.

Where door and window openings occur, the special “stops” to be adjusted and firmly secured so as to withstand hard ramming. Two 4 in. by 2 in. by 9 in. plugs to be built in to each window jamb for the securing of the frames and three to each door jamb.

Special care to be taken in the thorough ramming at the corners and along the box edges.

(8) Insert below floor level, where directed, 24 3-in. field drainage pipes to act as ventilators through the thickness of the wall. Insert wire mesh stops to exclude vermin.