Fig. 12.

One of eight. Plain Cylinder, 30ft. long, 6ft. diameter, 3/8 inch plates, 35 lbs. pressure. The plates were arranged longitudinally. Boiler had worked 27 years, and was much deteriorated, and gave way at an old fracture over the grate, and was torn into 4 pieces, which were thrown a great distance.

No.21. Huddersfield. ([Fig. 13.])

June 20th.

1 killed, 6 injured.

Fig. 13.

One tube Cornish, 24ft. long, 6ft. diameter. Tube 3ft. 3in. diameter, 3/8 inch plates, 40 lbs. pressure. The seams were arranged diagonally, but the rents had not followed the seams, but had torn the plates. The shell gave way where extensive corrosion had reduced the plates to 1/8 inch in thickness, and all the shell was blown off, and the tube thrown over and turned end for end.

No.22.