Remarks, and general rules.

The ground plan, and relief of bastioned fortifications are mutually dependent on each other; and, as a variety of causes occur to influence both according to the various sites occupied, it is impossible to give them any fixed arrangement, and dimensions, applicable under all circumstances. However, under the supposition that the site to be fortified is a horizontal plane, a great number, and variety of systems have been proposed at different times; almost every author, who has treated of fortification, having invented one, at least, of his own. Notwithstanding this diversity of opinion, as to the best system, all agree that the following general principles should not be lost sight of in the construction of fortifications.

1. Salient angles should be as large as possible, and never less than 60°. The larger they are the smaller will be the space in front undefended by direct fire. If less than 60°, the salients of earth are too acute to stand firmly for any length of time; and the angles of masonry are easily damaged; besides which the space within the parapets becomes too restricted to admit of a gun being worked near the angle.

2. Angles of defence should be right angles, or slightly obtuse. If less than right angles, the fire from the flanking works might injure the defenders of the works they flank; as troops generally, and more particularly at night, fire in a direction perpendicular to the parapet; and if too obtuse the fire might be directed wide of its object. Besides, embrazures should be cut as direct as possible; as the more they are oblique, the more they weaken the parapet.

3. The length of the lines of defence shall be such, that the works defended may be within the effective range of the projectiles used.

4. The works should be so disposed that the assailants may not be able to obtain cover in any part of the exterior, within range of the projectiles of the defenders.

5. The escarps of the body of the place should be of such height, or construction, as to be secure against escalade.

6. The masonry should be sufficiently covered from the view of the enemy, to prevent his making a practicable breach from a distance.

7. The interior of every work should be completely covered from the view of an enemy outside it; so that he may not be able to fire directly into any part of it. Interior works should therefore have a command over those in front of them, at least equal to the height which a besieger can give to the parapets of his lodgments, and which is seldom less than 3 feet.

8. Every opportunity should be seized of so directing the faces of works that an enemy may not have it in his power to enfilade them by ricochet fire.