Testing Ångström’s Aurora theory. Battery and spectroscope described. Vogel’s spectrum selected for comparison.

In order to test Professor Ångström’s theory of the Aurora, referred to in the last Chapter, in an experimental way, I examined, in the winter of 1874, some tube and other spectra, not only for line-positions, but also for general resemblance to an Aurora-spectrum. It did not seem desirable to use powerful currents. A ½-inch-spark coil, worked by a quart bichromate-cell, was found sufficient to illuminate the tubes steadily. The spectroscope used was one made for me by Mr. Browning specifically for Auroral purposes, and of the direct-vision form, being the same instrument as is described antè, p. 91, and figured in Plate X. fig. 1. The micrometer was the diaphragm one, also before described and figured on same Plate, figs. 2, 3, and 4. I selected Dr. Vogel’s spectrum for comparison, it being, so far as I am aware, the most accurately mapped, with regard to wave-length, at one observation, of any Auroral spectrum. It seemed an unsafe plan to attempt to obtain an average Aurora by comparison of different observations made at various times by different observers with all sorts of instruments—the difficulty, too, being increased by the suspicion that the spectrum itself at times varies in number and position as well as intensity of its lines.

Central part only of spectrum mapped.

In most cases the central part of the spectrum only (corresponding to the central lines of the Aurora) was mapped, the red line in the Aurora not being found to correspond with any prominent line in the gas-spectra examined, and the Auroral line near solar G being so indefinitely fixed as to render comparison almost valueless. (See Plate XIII. fig. 1.)

Dr. Vogel’s spectrum does not comprise the line near G; but I have added this (in an approximate place only) in order to complete the set of lines. For drawing of Dr. Vogel’s spectrum, with its scales attached, see Plate XIII.

Plate XIII.

Hydrogen-tube.

Hydrogen-tube. Colour of glow varied with intensity of current.

This tube was one of Geissler’s and of rather small calibre. On illumination the wide ends were easily lighted with a silver-grey glow, having a considerable amount of stratification. The capillary part glowed brilliantly with silver-white, bright green, and crimson light, according to the intensity of the current. With the commutator slowly working, white running into green and bright green were the main features of the thread of light; on the current passing more rapidly, the capillary thread became of an intense crimson, at the same time apparently increasing in diameter (an effect probably due to irradiation).