Figs. 3284, 3285, 3286, 3287.

[Figs. 3284], [3285], [3286], and [3287] show the setting for a half arch front boiler, the dimensions of the settings of both these boilers being given in the following tables:

MEASUREMENTS FOR SETTING TUBULAR STATIONARY BOILERS WITH FULL ARCH FRONTS.

REFERENCE LETTERS ON DIAGRAMS.
No.ABCDEFGHIJKLMNOPQRSTUNO. OF
FIRE
BRICK.
NO.
COMMON
BRICK
ABOVE
FLOOR
LEVEL.
Ft.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ft.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.
1 7321220164544 7326485261911-620401216363446006800
2 7341220164847 8346690262211-620401216363446007500
3 8361220164847 8366892262212-624401216363446507700
31⁄210361220164847 8366892262214-628461216424247208500
4 8421420164847 8427498272112-824401216363447308500
5 10421420164847 8427498272114-828461216424247709600
6 10441424164847 104476100272115-0284612164242488010500
7 124414241648461⁄2104476100272117-0325212164849494010800
71⁄2144414241647451⁄210447699262119-03658121654844112011500
8 124816241647451⁄2104888103262117-23252122048494112013600
9 144816241647451⁄2104888103262119-23658122054844114015700
10 125416242050481⁄2105494112262417-63252122048494116016200
101⁄2155416242050481⁄2105494112262420-83656162054904127017500
11 126018242050481⁄21260108118262417-103250162448494140020500
12 146018242050481⁄21260108118262419-103656162454844150023000
13 16601826205048 1260108118262422-04056162454964154025300
14 156618282050481⁄21266114124262421-23656162454904159026000
15 16661828205048 1266114124262422-24056162454964162027000
16 16722030205048 1272120130262422-64056162454964175030000
Note.—In setting“Standard” boilers, the side walls should be so built that thelongitudinal seams of the shell will be protected from the fire.

MEASUREMENTS FOR SETTING TUBULAR STATIONARY BOILERS WITH HALF ARCH FRONTS.

REFERENCE LETTERS ON DIAGRAMS.
No.ABCDEFGHIJKLMNOPQRSTUVWXYZNO. OF FIRE BRICK.NO. COMMON BRICK ABOVE FLOOR LEVEL.
Ft.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ft.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.Ins.
1 73214201646 45 7326473 26 20 10-32033 12163634436 9 241276006150
2 73414201646 45 8346675 26 20 10-32033 12163634436 9 281276006200
3 83614201646 45 8366877 26 20 11-32433 12163634436 9 2812156506700
31⁄2103614201646 45 8366877 26 20 13-32839 12164242436 9 2812257207050
4 84218201646 45 8427483 27 19 11-324321⁄2121636344323⁄4121⁄43216117307700
5 104218201646 45 8427483 27 19 13-328381⁄2121642424323⁄4121⁄43216257708700
6 104418241646 45 10447685 27 19 13-728381⁄2121642424323⁄4121⁄43616258808800
7 124418241646 441⁄210447685 27 19 15-732441⁄2121648494321⁄4121⁄43620359409300
71⁄2144418241646 441⁄210447685 27 19 17-736501⁄2121654844321⁄4121⁄436244511209500
8 124819241650 481⁄210488893 26 24 15-73248 122048494361⁄4121⁄4362035112011100
9 144819241650 481⁄210488893 26 24 17-73654 122054844361⁄4121⁄4362445114012900
10 125419242050 481⁄210549499 26 24 15-1132481⁄212204849434 141⁄2422035116013200
101⁄2155419242050 481⁄210549499 26 24 19-136521⁄216205490434 141⁄2422457127014200
11 1260212420463⁄4451⁄212601081013⁄426 203⁄416-13247 16244849431 141⁄2482037140016700
12 1460212420463⁄445 12601081013⁄426 203⁄418-13653 162454844301⁄2141⁄2482445150019200
13 1660212620463⁄445 12601081013⁄426 203⁄420-34053 162454964301⁄2141⁄2482465154021500
14 156624282047 451⁄21266114108 26 21 19-536521⁄216245490431 141⁄2542457159022100
15 166624282047 451⁄21266114108 26 21 20-540521⁄216245496431 141⁄2542465162023100
16 167224302048 461⁄21272120115 281⁄4193⁄420-740521⁄2162454964271⁄219 542465175026000
Note.—In setting “Standard” boilers,the side walls should be so built that the longitudinal seams of the shell will be protected from the fire.

THE EVAPORATIVE EFFICIENCIES OF BOILERS.