The rate of evaporation is given at 8 lbs. of water (from and at 212° Fahr.), for which the fuel required is
148,105 ÷ 8 = 18,513 lbs. of coal per hour.
For a rate of combustion of 15 lbs. of coal per hour per square foot of grate,
grate area = 18,513 ÷ 15 = 1,234 sq. ft.
For stationary boilers the usual ratio of heating surface to grate area is 35:1, accordingly the heating surface corresponding to this ratio is
1,234 × 35 = 43,190 sq.ft.
The above calculation is based on a rate of evaporation of 8 lbs. of water per lb. of coal and a rate of combustion of 15 lbs. of coal per sq. ft. of grate. For other rates the required grate area may be obtained from the following table:
| Pounds of water from and at 212° per pound of coal | Pounds of coal per h.p. per hour | Pounds of coal burned per square foot of grate per hour | |||||||||
| 8 | 10 | 12 | 15 | 20 | 25 | 30 | 35 | 40 | |||
| Square feet grate per horse power | |||||||||||
| Good coal and boiler | 10 | 3.45 | .43 | .35 | .28 | .23 | .17 | .14 | .11 | .10 | .09 |
| 9 | 3.83 | .48 | .38 | .32 | .25 | .19 | .15 | .13 | .11 | .10 | |
| Fair coal or boiler | 8.61 | 4. | .50 | .40 | .33 | .26 | .20 | .16 | .13 | .12 | .10 |
| 8 | 4.31 | .54 | .43 | .36 | .29 | .22 | .17 | .14 | .13 | .11 | |
| 7 | 4.93 | .62 | .49 | .41 | .33 | .24 | .20 | .17 | .14 | .12 | |
| Poor coal or boiler | 6.9 | 5. | .63 | .50 | .42 | .34 | .25 | .20 | .17 | .15 | .13 |
| 6 | 5.75 | .72 | .58 | .48 | .38 | .29 | .23 | .19 | .17 | .14 | |
| 5 | 6.9 | .86 | .69 | .58 | .46 | .35 | .28 | .23 | .22 | .17 | |
Lignite and poor boiler | 3.45 | 10. | 1.25 | 1.00 | .83 | .67 | .50 | .40 | .33 | .29 | .25 |
General Arrangement of Station.—In designing an electrical station, it is preferable that whatever rooms or divisions of the interior space are desired should determine the total outside dimensions of the plant in the original plans of the building than that these latter dimensions be fixed and the rooms, etc., be fitted in afterward.