These pumps are much used in connection with hydraulic elevators by pumping directly into the elevator cylinders, as there is no pulsation. They are also used to pump oil into pipe lines and are driven by electric motors as well as by belts. For circulating pumps for brine and for fire purposes these pumps have certain peculiar advantages.

Table of Dimensions and Capacities of the Quimby Screw Pump.

SizeGallons
Per
Minute
Revolutions
per
Minute
PIPINGEXTREME DIMENSIONS
SuctionDischarge
from
Valve Hood
DischargeWidthLengthHeight
2 7-101200 114 1 92711
212 15-201200 2 112 93214
3 30-351200 212 212 212103816
312 70-851200 4 3 3114925
4140-1701200 4 3 4135428
5200-2451100 5 4 5146431
6275-350 900 6 5 6177537
7400-485 775 8 6 8187838
9650-800 72510 810259248
10825-1000 575121012329860
Dimensions in inches.Weights in pounds.

AERMOTOR
PUMPS

Fig. 459.

AERMOTOR PUMPS.