The water line being carried in this larger part of the shell, tends to prevent the rapid fluctuation of the water level, and the increased area of its surface at this point is favorable to the disengagement of the steam.

Sectional Unit
for Outer-Tube
System.
Fig. 399.

Sectional Unit for
Inner-Tube System.
Fig. 400.

When held at its normal point, the water line protects the flanged part of the inner shell; but no damage can occur, either from a willful or an accidental drawing down of the water, as the spray deflected through the nipples of the outer tubes is sufficient to protect the flange, although the actual water level is well down in the leg.

The steam in contact with the upper part of the shell is by no means dry, and the heat absorbed at this point is amply sufficient to protect it. To insure a delivery of dry steam to the cylinders, a peculiar “take-off” ring is provided at the highest part of the steam reservoir, the same encircling the inside sheet of the shell. The upper edge of the ring is perforated at a distant point from the throttle, and the steam entering the ring chamber in small streams is held in close contact with the hot shell at a point closely adjacent to the upper line of rivets; the steam by this means is dried during its passage to the throttle, and the heat thus absorbed serves as a protection to the rivets just referred to.

Note.—The life of both water tubes and fire tubes is generally found disproportionate to the heavier parts used in boiler construction, and experience shows conclusively that the cost of subsequent maintenance is measured directly by, and may be diminished by, the facility with which these indispensable parts may be replaced or repaired in an emergency.

The principal heating surface of the boiler is contained in the vertical water tube sections, which comprise and will be referred to, as an inner and an outer tube system.