Charging Rates

Fill batteries listed in Table No. 1 with 1.270 sp. gr. acid.

TABLE — No. 1

No. of Plates LL-LLR
and LH
LM
LMR
LT
LTR
LS
LSR
LG LT LSF
9 2.0 2.5 2.0 2.5 3.0
11 2.5 3.0 2.5 3.5 4.0
13 3.0 3.5 3.0 4.0 2.5
15 3.5 4.0 3.5 4.5 5.5
17 4.0 5.0 4.0 5.5 6.0
19 4.5 5.5 4.5 6.0

Special Battery: 136 USA................6. 0 amps.

TABLE NO.2

Fill batteries listed in Table No. 2 with 1.250 sp. gr. acid.

No. of Plates LL-LLR
and LLH
LM
LMR
LT
LTR
LS
LSR
S
SH
ST LSF
5 1.0 1.0 2.0 1.5
7 1.5 1.5 1.5 2.0 3.0 2.0 1.5
9 4.0
11 5.0

Special Batteries: 330 AA ............ 1.0 amps.
524 STD-H2 ............ 1.0 amps.
7 6 SPN ............ 1.5 amps.

The number of plates per cell is; indicated in the first numeral of the type name. For instance, 712 LLA-1 is a 7 plate LL. For all lighting batteries, types S and ST. use 1.210 electrolyte.