[C]

Cadmium. What it is [176] Cadmium leads. Connection of, to voltmeter [179] Cadmium readings affected by improperly treated separators [181] Cadmium readings. Conditions necessary to obtain good negative-cadmium readings [210] Cadmium readings do not indicate capacity of a cell [175] Cadmium readings on short-circuited cells [180] Cadmium readings. Troubles shown by, on charge [206] Cadmium readings. When they should be taken [176] Cadmium test [174] Cadmium test. How made [175] Cadmium test on charging battery [181] Cadmium test on discharging battery [180] Cadmium test set. What it consists of [177] Cadmium test voltmeter [178] Calling for repair batteries [314] Capacity. Effect of age of battery on [47] and [89] Capacity. Effect of plate surface area on [42] Capacity. Effect of clogged separators on [88] Capacity. Effect of incorrect proportions of acid and acid in electrolyte on [88] Capacity. Effect of low level of electrolyte on [88] Capacity. Effect of operating conditions on [44] Capacity. Effect of quantity and strength of electrolyte on [42] Capacity. Effect of quantity, arrangement, and porosity of active materials on [42] Capacity. Effect of rate of discharge on [44] Capacity. Effect of reversal of plates on [89] Capacity. Effect of shedding on [88] Capacity. Effect of specific gravity on [43] Capacity. Effect of temperature on [46] Carbon-arc lead-burning outfit [148] Carboys [184] Care of battery on the car [51] to [68] Care of battery when not in service [67] Carrier for batteries [173] Case. Cleaning and painting, after repairs [372] Case manufacture [22] Case. Painting, after bench charge [203] Case. Repairing [360] Case. Troubles indicated by rotted [319] Case troubles [83] Cases. Equipment for work on [98] and [170] Casting plate grids [9] Cell connector mould [168] Cell connectors. Burning-on [213] Cell connectors. Equipment for work on [98] Cell connectors. How to remove [329] Changing pastes into active materials [12] Charge. [(See Bench Charge.)] Charge. Changes at negative plates during [30] and [39] Charge. Changes at positive plates during [30] and [40] Charge. Changes in acid density during [39] Charge. Changes in voltage during [38] Charge. Loss of, in an idle battery [89] Charge. Preliminary, in rebuilding batteries [349] Charge. Trickle [239] Charging bench[133] to [139] Charging bench. Arrangement of batteries on [200] Charging bench. Temperature of batteries on [202] Charging bench. Working drawings of [134] to [139] Charging circuits. Drawings of [105] Charging connections. Making temporary [220] Charging. Constant potential [111] Charging equipment for farm lighting batteries [439] Charging equipment for starting batteries [100] Charging farm lighting batteries [455] Charging. Lamp-banks for [101] Charging. Motor-generators for [106] Charging rate. Adjusting [287] Charging rate. Checking [283] Charging rate. Governed by gassing [112] and [202] Charging rate. How and when to adjust [289] Charging rates for bench charge [112] and [201] Charging rates for new Exide batteries [226] Charging rates for new Philadelphia batteries [228] Charging rates for new Prest-O-Lite batteries [234] Charging rates on the car [283] Charging rebuilt batteries [373] Charging. Rheostats for [101] Chemical actions and electricity. Relations between [31] Chemical changes at the negatives during charge [30] Chemical changes at the positives during charge [30] Chemical changes at the negatives during discharge [29] Chemical changes at the positives during discharge [29] Chemical changes in the battery [27] to [31] Composition of jars [16] Composition of plate grids [9] Compound. Scraping, from covers and jars [334] Compressed air and hydrogen lead-burning outfit [147] Compressed air and illuminating gas lead-burning outfit [149] Condenser for making distilled water [160] Connections. Making temporary, for charging [220] Connectors. (See [Cell Connectors].) Connector troubles [84] Constant-potential charging [111] Construction of plate grids [10] Convenient method of adding water [56] Corroded grids [77] Corroded grids. Caused by age [78] Corroded grids. Caused by high temperatures [78] Corroded grids. Caused by impurities [78] Corrosion [321] Covers. Eveready [17] Covers. Exide [19] and [21] Covers. Functions of [16] Covers. Gould [17] Covers. How to remove [331] Covers. Philadelphia diamond grid [16] Covers. Prest-O-Lite [18] and [19] Covers. Putting on the [365] Covers. Sealing [366] Covers. Single and double [16] Covers. Steaming [332] Covers. U.S.L. [18] and [20] Covers. Vesta [18] Covers. Westinghouse [417] Covers. Willard [19] Credit. Use and abuse of [301] Cutout. Checking action of [282] Cycling discharge tests [269]

[D]

Dead cells. Causes of [87] Delco-Light batteries [466] Delco-Light batteries. Ampere-hour meter for [467] and [471] Delco-Light batteries. Burning-on new plates of [492] Delco-Light batteries. Burning-on new straps for [488] Delco-Light batteries. Care of cells of, in stock [493] Delco-Light batteries. Charging, after reassembling [481] Delco-Light batteries. Charging outside negatives of [484] Delco-Light batteries. Clearing high resistance shorts in [484] Delco-Light batteries. Clearing lug shorts in [484] Delco-Light batteries. Dis-assembling [474] Delco-Light batteries. Gauges and instruments for testing [466] Delco-Light batteries. General complaints from users of [495] Delco-Light batteries. Hydrometers for [468] Delco-Light batteries. Inspection trips [470] Delco-Light batteries. Pressing negatives of [485] Delco-Light batteries. Putting repaired cells into service [484] Delco-Light batteries. Re-assembling [477] Delco-Light batteries. Removing impurities from [483] Delco-Light batteries. Repairing broken posts of [487] Delco-Light batteries. Repairing lead parts of [486] Delco-Light batteries. Salvaging replaced cells of [486] Delco-Light batteries. Taking, out of commission [494] Delco-Light batteries. Treating broken cells of [482] Delco-Light batteries. Treating spilled cells of [482] Delco-Light batteries. Treating reversed cells of [483] Delco-Light batteries. Use of auxiliary straps with [492] Delco-Light batteries. When and how to charge [468] Discharge apparatus [270] Discharge. Changes at negative plates during [37] Discharge. Changes at positive plates during [37] Discharge. Changes in acid density during [35] Discharge. Chemical actions at negative plates during [29] Discharge. Chemical actions at positive plates during [29] Discharge. Effects of rates of, on capacity [44] Discharge. Voltage changes during [32] Discharge tests. Cycling [269] Discharge tests. Fifteen seconds [266] Discharge tests. Lighting ability [267] Discharge tests. Starting ability [267] Distilled water. Condenser for making [160] Dope electrolytes [59] and [199] Double covers. Sealing [366] Dry shipment of batteries [24] Dry storage [240] Dry storage batteries [265]

[E]

Earthenware jars [184] Electrical system. Normal course of operation of [277] Electrical system. Testing the [276] Electrical system. Tests on, to be made by the repairman [279] Electrical system. Troubles in the [284] Electricity and chemical actions. Relation between [31] Electrolyte. Adjusting the [373] Electrolyte below tops of plates. Causes and results of [319] and [323] Electrolyte. Causes of milky appearance of [206] Electrolyte. Composition of [199] and [222] Electrolyte. Correct height of, above plates [55] Electrolyte. Effect of circulation of, on capacity [44] Electrolyte. Effect of low [67] Electrolyte. Effect of quantity and strength of, on capacity [42] Electrolyte. Freezing points of [67] Electrolyte. Leaking of, at top of cells [324] Electrolyte. Level of, at end of bench charge [203] Electrolyte. Resistance of [43] and [48] Electrolyte troubles. High gravity [85] Electrolyte troubles. High level [85] Electrolyte troubles. Low gravity [85] Electrolyte troubles. Low level [85] Electrolyte troubles. Milky appearance [85] Element. Tightening loose [363] Elements. Re-assembling [361] Equipment for discharge tests [270] Equipment for general work [98] Equipment for general work on connectors and terminals [98] Equipment for handling sealing compound [149] Equipment for lead-burning [97] Equipment for work on cases [98] and [170] Equipment needed in opening batteries [97] Equipment which is absolutely necessary [96] Eveready batteries. Claimed to be non-sulphating [401] Eveready batteries. Description of parts [404] Eveready batteries. Rebuilding [405] Examining and testing incoming batteries [317] Exide farm lighting batteries [466] to 498 Exide radio batteries [257] Exide starting batteries. Age code for [243] Exide starting batteries. Burning-on cell connectors of [382] Exide starting batteries. Capacities of [381] Exide starting batteries. Charging, after repairing [382] Exide starting batteries. Methods of holding jars of, in case [377] Exide starting batteries. Opening of [377] Exide starting batteries. Putting cells of, in case [382] Exide starting batteries. Putting jars of, in case [382] Exide starting batteries. Putting new, into service [225] Exide starting batteries. Re-assembling plates of [379] Exide starting batteries. Sealing single covers of [380] Exide starting batteries. Type numbers of [377] Exide starting batteries. Types of [375] Exide starting batteries. Work on plates, separators, jars, and cases of [379]

[F]

Farm lighting batteries [435] to [510] Farm lighting batteries. Care of, in operation [453] Farm lighting batteries. Care of plant of, in operation [450] Farm lighting batteries. Charging [453?] or [(455)] Farm lighting batteries. Charging equipment for [439] Farm lighting batteries. Determining condition of cells of [453] Farm lighting batteries. Difference between, and starting batteries [435] Farm lighting batteries. Discharge rules for [457] Farm lighting batteries. Exide [466] Farm lighting batteries. Initial charge of [448] Farm lighting batteries. Installation of plant [445] Farm lighting batteries. Instructing users of [449] Farm lighting batteries. Jars used in [436] Farm lighting batteries. Loads carried by [443] Farm lighting batteries. Location of plant [444] Farm lighting batteries. Overcharge of [455] Farm lighting batteries. Power consumed by appliances connected to [442] Farm lighting batteries. Prest-O-Lite [460] Farm lighting batteries. Selection of plant [440] Farm lighting batteries. Separators for [438] Farm lighting batteries. Size of plant required [442] Farm lighting batteries. Specific gravity of electrolyte of [438] Farm lighting batteries. Troubles with [458] Farm lighting batteries. When to charge [455] Farm lighting batteries. Wiring of plant for [444] Filling and testing service [291] Flames for lead-burning [211] Floor. Care of [188] Floor grating for shop [188] Floor of shop [186] Forming plates [11] Freezing points of electrolyte [67]

[G]

Gassing causes shedding [74] Gassing. Charging rate governed by [112] and [202] Gassing. Definition of [31] Gassing. Excessive, causes milky appearance of electrolyte [86] Gassing of sulphated plates [40] and [75] Gassing on charge [37?] and [202] Granulated negatives [78] Granulated negatives. Caused by age [78] Granulated negatives. Caused by heat [78] Gravity. (See Specific Gravity). Grids. Casting [9] Grids. Composition of [9] Grids. Corroded [77] Grids. Effect of age on [78] and [80] and 342? ([344]) Grids. Effect of defective grid alloy on [73] Grids. Effect of impurities on [77] and [78] and [80] and [342] Grids. Effect of overheating on [78] and [80] and [342?] Grids. Resistance of [48] Grids. Trimming [10]