EMERALD GREEN.

White Sectors. Reading of Spectrum Scale.
Original Setting.White Corrected For Black.Corrected White 100.
White. Black.
10 350 27·5 7·65 50
20 340 37·0 10·15 54
30 330 46·5 12·95 55
50 310 65·5 18·10 57·5
70 290 84·5 23·5 60·0
90 270 103·5 29·7 63·5
110 250 122·5 34·7 65·5
130 230 141·5 39·5 67·5
150 210 160·5 45·0 68·5
170 190 179·5 50·0 71
190 170 195·5 54·7 73·5
210 150 217·5 60·2 75·0
220 140 227 63·2 76
220 140 227 63·2 78
210 150 217·5 60·2 80
190 170 198·5 54·7 82
170 190 179·5 50·0 83
150 210 160·5 45·0 84
130 230 141·5 39·5 85
110 250 122·5 34·7 86·5
90 270 103·5 29·7 87·5
70 290 84·5 23·5 88·5
50 310 65·5 18·10 90·0
30 330 46·5 12·95 92
20 340 37·0 10·15 94
10 350 27·5 7·65 98

FRENCH ULTRAMARINE BLUE.

White Sectors. Reading of Spectrum Scale.
Original Setting.White Corrected For Black.Corrected White 100.
White. Black.
0 360 18·0 5·0 84
10 350 27·5 7·65 80
20 340 37·0 10·15 77
30 330 46·5 12·95 75
40 320 56·0 15·6 74
60 300 75·0 20·7 72·5
80 280 94·0 25·5 70·5
100 260 113·0 32·5 68
120 240 132·0 37·2 66·5
140 220 151·0 42·3 62·5
160 200 170·0 47·4 59·5
170 190 179·5 50·0 55
160 200 170·0 47·4 51
140 220 151·0 42·3 46
0 360 18·0 5·0 95
10 350 27·5 7·65 98
20 340 37·0 10·15 99
30 330 46·5 12·95 110

These three measurements have been given in full, since they will be useful for reference when other experiments are described.

Fig. 16.—Method of obtaining two Patches of identical Colour.