| C = √ | (Drainage area in acres)3 |
C being variable according to circumstances thus:
"For steep and rocky ground C varies from 2/3 to 1. For rolling agricultural country, subject to floods at times of melting snow, and with length of valley three or four times its width, C is about 1/3, and if stream is longer in proportion to the area, decrease C. In districts not affected by accumulated snow, and where the length of valley is several times its width, 1/5 or 1/6 or even less may be used. C should be increased for steep side slopes, especially if the upper part of the valley has a much greater fall than the channel at the culvert. The value of C to be used in any case is determined after an inspection of the drainage area."
Fig. 2. Design of Pipe Culvert and Bulkhead
Length of Culvert.—The clear length between end walls on a culvert should be at least equal to the width of the roadway between ditches. This is a minimum of 20 feet for secondary roads and ranges from 24 to 30 feet for main roads. The headwall to the culvert should not be a monument, but should be no higher than needed to prevent vehicles from leaving the roadway at the culvert.
Farm Entrance Culverts.—At farm entrances, culverts are required to carry the farm driveway across the side ditch of the road. These culverts are usually about 16 feet along, and should be of a size adequate to take the flow of the side ditch. The farm entrance culvert should be of such design that it can be easily removed to permit cleaning out the ditches with a road grader.
Types of Culverts
Culverts constructed of concrete and poured in place are called box culverts because of the rectangular form of the cross section. Culverts of pre-cast pipe are known as pipe culverts. Several forms of pipe culvert are in general use.