A. First see that no one is working under the engine, that there is the proper amount of water in the boiler and that it will flow through the gauge cocks, that there is no accumulation of oil in the ash-pan or fire-box or existing leaks throughout. If there is no steam in the boiler, the steam connections can be made to the three-way cock at the smoke-arch that will answer for blower and atomizer. If there are twenty pounds of steam in the boiler, it can be operated with its own blower. If oil in the tank is too cold to flow into the burner readily, it must be heated. Open the front damper and put on the blower strong enough to create the necessary draft, open the atomizer valve long enough to blow out any water that might be in the steam pipe to the burner, then close the valve and throw a piece of burning waste in front of the burner and open the atomizer valve enough to carry oil to the burning waste and open the regulating valve slowly until the oil is known to be ignited. Watch the ignition through the hole in the fire-box door, then regulate the steam and oil supply to suit. Be sure that no oil is wasting below the burner or an explosion may result that will prove disastrous.
11. Q. Should the fire go out and it is desired to rekindle it while bricks are hot, is it safe to depend on the hot bricks to ignite the oil without the use of lighted waste?
A. No; depending upon the heat from the firebricks to re-light the fire is dangerous and forbidden.
12. Q. What is termed an atomizer, and what does it perform?
A. The atomizer is a casting containing two long ports with an extension lip; the upper port is for oil and the lower one for steam. The lip aids the steam in atomizing and spreading the oil, which, when properly mingled with the air and ignited, will produce combustion. The atomizer is located just under the mud-ring and pointed a little upward, so the stream of oil and spray of steam would strike the opposite wall a few inches above the bottom if it would pass clear across the fire-box.
13. Q. In starting or closing the throttle of the locomotive, how should the fireman regulate the fire, in advance or after the action of the engineer?
A. In starting an oil burning engine the oil should gradually be brought up as the throttle is opened and the movement and amount of oil should be kept slightly in advance of the action of the engineer in order to prevent an inrush of cold air as the engine is working, which would result in injury to the fire-box and flues. When the throttle is to be closed, the fire should be reduced very slightly in advance of the closing of the throttle. This is to prevent the engine from popping off and black smoke drifting back over the train.
14. Q. Is it necessary that the engineer and fireman on an oil burning locomotive work in perfect harmony and advise each other of intended action at every change of conditions?
A. Yes; they should work in harmony with each other on any locomotive. The fireman should watch every move the engineer makes, and the engineer should advise the fireman of every intended change of the throttle, so he can operate his valves accordingly and save fuel and avoid black smoke.
15. Q. What is the effect of forcing the fire on an oil burning locomotive?