107. Q. If the steam heat gauge shows proper pressure, but the steam heat pipe pressure appears to be low, what should be done?

A. If the steam heat gauge is showing the correct pressure, there is an obstruction in the pipe somewhere, most likely in the steam heat hose, and this should be looked for and remedied; if the gauge is correct, then it is the reducing valve that is at fault and this should be readjusted, as well as the gauge.

108. Q. What is the cause of failure with the second injector, and what should be done to obviate this failure?

A. Lack of attention and failure to use every day will allow joints to work loose and boiler check to fill up with mud and scale. It should be tested every day and worked regularly so as to keep it in good working order.

109. Q. If an injector stops working while on the road, what should you do?

A. Would first ascertain if sufficient water was in the tender and tender valve open, and that water was cool enough in the tender so the injector would handle it. Would next see that no obstruction was in the feed pipe or strainer and that the feed pipe was free from leaks, and that the injector was getting a sufficient supply of steam. If the injector would not prime, would see whether overflow or heater valve could open wide, or if overflow pipe was obstructed. If suction pipe was very hot would blow water back into tank and let suction fill with cold water. If possible, examine for obstruction in the steam priming tube and water tubes. If it would prime and fail to deliver water to the boiler, would see that the delivery tube was not obstructed and then look for trouble at the boiler check. An obstruction in the tubes would stop the injector working at once, while wear of the tubes or filling up with scale would affect the injector gradually.

110. Q. What are the advantages of the combination boiler check and stop valve?

A. A combination boiler check is fitted with a valve similar to a globe valve and can be closed at will. Its advantage is that the boiler pressure can be shut off from the check and the valve repaired without cooling the boiler. This hand-operated valve can be closed to prevent the boiler water passing back in case the check valve sticks up and allows the boiler water to pass back to the injector when not working.

111. Q. How can a disconnected tank valve be opened without stopping?

A. Close the overflow or heater valve and turn steam back toward the tank; this will usually lift the valve from its seat or turn it around so it opens.