b. The same procedure applies to round‐type air cleaners used on earlier models.
79. INSTALL AIR CLEANER.
a. Engage air cleaner hose connection in end of hose and mount cleaner assembly on frame bracket with two bolts, gear‐toothed lock washers, and nuts. Securely tighten mounting nuts. NOTE: The plated (whitened) mounting bolts, four gear‐toothed lock washers, and bolt nuts must effect a ground connection between bracket and filter mounting to insure adequate radio bonding. Tighten air hose clamp screw at cleaner body connection.
b. The same procedure applies to round‐type air cleaners used on earlier models.
80. REPLACEMENT OF AIR CLEANER MOUNTING BRACKET.
a. Air cleaner mounting bracket and air cleaner can be removed or installed as an assembly.
b. Remove.
(1) Loosen hose clamp connection at air cleaner body.
(2) Disconnect battery ground wire. This prevents shorting battery when removing cleaner bracket clamp bolt.