c. Remove Adjustable Contact Point.
(1) Remove the two lock screws and washer plate, securing adjustable contact point assembly to timer base. Point assembly is free to be lifted off lever pivot stud.
d. Install Adjustable Contact Point.
(1) Install contact point assembly, replacing washer plate and the two lock screws. Do not tighten lock screws until circuit breaker points are adjusted (step f below).
e. Install Breaker Lever.
(1) Install brass terminal strip on primary wire binding post.
(2) Connect end of brass terminal strip to condenser terminal post. Install flat washer, gear‐toothed washer, and nut.
(3) Install breaker lever on pivot post insulated bearing.
(4) Install breaker lever spring. Make sure that ends of spring are retained correctly.
(5) NOTE: Keep breaker lever cam very lightly greased.