(1) Nitrogen contained in fifteen 220-cubic-foot cylinders or an equivalent volume of compressed air. (Eleven cylinders are expended if the four-place arrangement described in Paragraph 32 is used.)
(2) 450 gallons of fuel (400 gallons plus 50 gallons for spillage, spoilage, and evaporation).
(3) 100 ignition cylinders.
(4) If thickened fuel is used, 135 pounds (in cans of 5-1/4 pounds each) of U. S. Army fuel thickener.
Section III TOOLS, PARTS, AND ACCESSORIES
10. ITEMS WITH EACH FLAME THROWER.
The items listed below or their equivalents ([Fig 7]) are included in each M2-2 flame-thrower packing chest, in addition to the flame thrower. Numbers listed with items are Chemical Warfare Service stock numbers.
a. Kit, tool, for portable flame thrower M2-2, assembly B81-6-50.
b. Kit, spare parts, for portable flame thrower M2-2, assembly B81-6-52.