h. Remove spare parts kit, tool kit, cans of ignition cylinders, and other items from packing chest.
i. Compare contents with packing list found in or on packing chest. Inspect all contents carefully for completeness, correct adjustment, and good condition.
j. Insert deflector tube in safety head on left fuel tank. ([Fig 11]) Outlet should face to rear and at a 45-degree angle to operator’s left shoulder. ([Fig 18]) Screw in deflector tube by hand; do not use wrench on deflector tube. Tighten lock nut with wrench.
k. Before use on a mission, test-fire the weapon. ([Par 56 b])
l. Save the packing chest for storage of the equipment when flame thrower is not being carried on a firing mission or serviced.
13. USED EQUIPMENT.
When they apply, the same steps should be taken as in Paragraph [12]. Any worn or damaged parts should be replaced. Areas where paint has worn off should be touched up with fresh paint.
Section VI CONTROLS
14. CONTROLS.
The firer uses the pressure-tank valve handle, the trigger, and the valve lever and grip safety ([Fig 12]) in succession as follows: