56. SERVICE AFTER SIX FIRING MISSIONS.

After the flame thrower has been used on six firing missions or the equivalent in training work, experienced personnel should follow these directions:

a. Before-operation and after-operation service. Follow the same procedures as in Paragraphs 52, 53, and 55.

b. Test firing (or simulated firing).

(1) If tactical conditions permit test firing at a suitable test range ([Par 15]), fill the fuel tanks with fuel. (Pars [37] through [40])

(2) If test firing with fuel is impracticable, fill fuel tanks with clean water. (Be sure to dry all parts after test.)

(3) Remove filling-plug assembly. ([Par 69]) Fish out the retainer rod and chain by means of a bent wire.

(4) Do not unscrew the safety-head plug.

(5) Insert the testing plug with 0-to 500-pound pressure gage (plug and gage are from service kit) in the filling-plug opening. Tighten testing plug in seat with wrench.