Considering the accuracy of these measures (an accuracy far surpassing that of any other contemporary observations), it is somewhat surprising that this form of micrometer was never systematically used in any sustained or important astronomical researches, although a number of instruments of the kind were made by Dollond. Probably the last example of its employment is an observation of the transit of Mercury (November 4, 1868) by Mann, at the Royal Observatory, Cape of Good Hope (Monthly Notices R.A.S. vol. xxix. p. 197-209). The most important part, however, which this type of instrument seems to have played in the history of astronomy arises from the fact that one of them was in the possession of Bessel at Königsberg during the time when his new observatory there was being built. In 1812 Bessel measured with it the angle between the components of the double star 61 Cygni and observed the great comet of 1811. He also observed the eclipse of the sun on May 4, 1818. In the discussion of these observations (Königsberger Beobacht, Abt. 5, p. iv.) he found that the index error of the scale changed systematically in different position angles by quantities which were independent of the direction of gravity relative to the position angle under measurement, but which depended solely on the direction of the measured position angle relative to a fixed radius of the object-glass. Bessel attributed this to non-homogeneity in the object-glass, and determined with great care the necessary corrections. But he was so delighted with the general performance of the instrument, with the sharpness of the images and the possibilities which a kindred construction offered for the measurement of considerable angles with micrometric accuracy, that he resolved, when he should have the choice of a new telescope for the observatory, to secure some form of heliometer.

Nor is it difficult to imagine the probable course of reasoning which led Bessel to select the model of his new heliometer. Why, he might ask, should he not select the simple form of Dollond’s first type? Given the achromatic object-glass, why should not it be divided? This construction would give all the advantage of the younger Dollond’s object-glass micrometer, and more than its sharpness of definition, without liability to the systematic errors which may be due to want of homogeneity of the object-glass; for the lenses will not be turned with respect to each other, but, in measurement, will always have the same relation in position angle to the line joining the objects under observation. It is true that the scale will require to be capable of being read with much greater accuracy than 1⁄1000th of an inch—for that, even in a telescope of 10 ft. focus, would correspond with 2″ of arc. But, after all, this is no practical difficulty, for screws can be used to separate the lenses, and, by these screws, as in a Gascoigne micrometer, the separation of the lenses can be measured; or we can have scales for this purpose, read by microscopes, like the Troughton[1] circles of Piazzi or Pond, or those of the Carey circle, with almost any required accuracy.

Whether Bessel communicated such a course of reasoning to Fraunhofer, or whether that great artist arrived independently at like conclusions, we have been unable to ascertain with certainty. The fact remains that before 1820[2] Fraunhofer had completed one or more of the five heliometers (3 in. aperture and 39 in. focus) which have since become historical instruments. In 1824 the great Königsberg heliometer was commenced, and it was completed in 1829.

To sum up briefly the history of the development of the heliometer. The first application of the divided object-glass and the employment of double images in astronomical measures is due to Savary in 1743. To Bouguer in 1748 is due the true conception of measurement by double image without the auxiliary aid of a filar micrometer, viz. by changing the distance between two object-glasses of equal focus. To Dollond in 1754 we owe the combination of Savary’s idea of the divided object-glass with Bouguer’s method of measurement, and the construction of the first really practical heliometers. To Fraunhofer, some time not long previous to 1820, is due, so far as we can ascertain, the construction of the first heliometer with an achromatic divided object-glass, i.e. the first heliometer of the modern type.

The Modern Heliometer.

Fig. 8.

The Königsberg heliometer is represented in fig. 8. No part of the equatorial mounting is shown in the figure, as it resembles in every respect the usual Fraunhofer mounting. An adapter h is fixed on a telescope-tube, made of wood, in Fraunhofer’s usual fashion. To this adapter is attached a flat circular flange h. The slides carrying the segments of the divided object-glass are mounted on a plate, which is fitted and ground to rotate smoothly on the flange h. Rotation is communicated by a pinion, turned by the handle c (concealed in the figure), which works in teeth cut on the edge of the flange h. The counterpoise w balances the head about its axis of rotation. The slides are moved by the screws a and b, the divided heads of which serve to measure the separation of the segments. These screws are turned from the eye-end by bevelled wheels and pinions, the latter connected with the handles a′, b′. The reading micrometers e, f also serve to measure, independently, the separation of the segments, by scales attached to the slides; such measurements can be employed as a check on those made by the screws. The measurement of position angles is provided for by a graduated circle attached to the head. There is also a position circle, attached at m to the eye-end, provided with a slide to move the eye-piece radially from the axis of the telescope, and with a micrometer to measure the distance of an object from that axis. The ring c, which carries the supports of the handles a′, b′, is capable of a certain amount of rotation on the tube. The weight of the handles and their supports is balanced by the counterpoise z. This ring is necessary in order to allow the rods to follow the micrometer heads when the position angle is changed. Complete rotation of the head is obviously impossible because of the interference of the declination axis with the rods, and therefore, in some angles, objects cannot be measured in two positions of the circle. The object-glass has an aperture of 6½ in. and 102 in. focal length.

There are three methods in which this heliometer can be used.

First Method.—One of the segments is fixed in the axis of the telescope, and the eye-piece is also placed in the axis. Measures are made with the moving segment displaced alternately on opposite sides of the fixed segment.

Second Method.—One segment is fixed, and the measures are made as in the first method, excepting that the eye-piece is placed symmetrically with respect to the images under measurement. For this purpose the position angle of the eye-piece micrometer is set to that of the head, and the eye-piece is displaced from the axis of the tube (in the direction of the movable segment) by an amount equal to half the angle under measurement.