The writer does not attempt here to apportion the two effects in any other way than to say that the greater part of the flexure appears to be due to the secondary cause. Consistent with this view of the matter is the fact that the inclination of the girder towards the rails greatly exceeded the calculated slope of the Barlow rail-ends when under load, being about five times as great. The inference is that the floor rails bore hard at their extreme ends, at which point of bearing the calculated twisting moment accounts for less than one-half of the flexure observed in the flanges.

Fig. 5.

The girders upon removal in the course of reconstruction again took the straight form, showing that the very frequent development of the stresses named had not sensibly injured the metal, though the bridge carried as many as three hundred trains daily in each direction, and had done so for very many years.

The deformation of the top flange only has been noticed, yet the same tendency exists in the bottom, though the actual amount is much less, both because the lower flanges are in tension, and are also in great degree confined by the frictional contact of the cross bearers, even where no proper ties are used. In the case dealt with the bottom flanges of the outer girders curved 18 inch outwards only.