PERMANGANATE PROCESS FOR THE DETERMINATION OF IRON

Potassium permanganate oxidizes ferrous salts in cold, acid solution promptly and completely to the ferric condition, while in hot acid solution it also enters into a definite reaction with oxalic acid, by which the latter is oxidized to carbon dioxide and water.

The reactions involved are these:

10FeSO_{4} + 2KMnO_{4} + 8H_{2}S_{4} —> 5Fe_{2}(SO_{4}){3} + K{2}SO_{4} + 2MnSO_{4} + 8H_{2}O

5C_{2}H_{2}O_{4}(2H_{2}O) + 2KMnO_{4} +3H_{2}SO_{4} —> K_{2}SO_{4} + 2MnSO_{4} + 10CO_{2} + 1 H_{2}O.

These are the fundamental reactions upon which the extensive use of potassium permanganate depends; but besides iron and oxalic acid the permanganate enters into reaction with antimony, tin, copper, mercury, and manganese (the latter only in neutral solution), by which these metals are changed from a lower to a higher state of oxidation; and it also reacts with sulphurous acid, sulphureted hydrogen, nitrous acid, ferrocyanides, and most soluble organic bodies. It should be noted, however, that very few of these organic compounds react quantitatively with the permanganate, as is the case with oxalic acid and the oxalates.

Potassium permanganate is acted upon by hydrochloric acid; the action is rapid in hot or concentrated solution (particularly in the presence of iron salts, which appear to act as catalyzers, increasing the velocity of the reaction), but slow in cold, dilute solutions. However, the greater solubility of iron compounds in hydrochloric acid makes it desirable to use this acid as a solvent, and experiments made with this end in view have shown that in cold, dilute hydrochloric acid solution, to which considerable quantities of manganous sulphate and an excess of phosphoric acid have been added, it is possible to obtain satisfactory results.

It is also possible to replace the hydrochloric acid by evaporating the solutions with an excess of sulphuric acid until the latter fumes. This procedure is somewhat more time-consuming, but the end-point of the permanganate titration is more permanent. Both procedures are described below.

Potassium permanganate has an intense coloring power, and since the solution resulting from the oxidation of the iron and the reduction of the permanganate is colorless, the latter becomes its own indicator. The slightest excess is indicated with great accuracy by the pink color of the solution.