The Sewerage System

There are two types of sewerage systems in use, the separate and the combined. In the former the storm water is removed in one set of pipes and the domestic sewage in another. The combined system removes both in the same set of pipes. In deciding which system to adopt three factors must be first considered, the cost, the topography of the city and the method of disposal. The general conclusions of sanitary engineers at present regarding the relative merits of the two systems are that either is satisfactory from a sanitary point of view when properly constructed, that the separate system is usually best for suburban districts not closely built up and for all communities where the sanitary sewage requires treatment, and that often a combination of the two systems can be used to advantage. Most engineers point to the advantage of combined sewers in narrow streets and congested districts where only one pipe and one house connection are required.

The belief has been expressed by John H. Gregory, consulting engineer, that as a general proposition the cost of building a combined system is less than that of constructing a separate system, especially where the territory to be served is more or less closely built up and streets paved. In suburban territory, not closely built up and where storm water is easily and quickly diverted into natural water courses, he believes the separate system will in general cost less, for then only sanitary sewers need to be built first, the storm water sewers being deferred for years or only such drains constructed as are immediately required. When there are steep grades and relatively high velocity all authorities agree with Gregory that it is advisable to build combined sewers, even though the development of the territory may hardly be such as to require the removal of the storm water.

Discussing the merits of the two systems so far as they affect the cost of disposal Clark P. Collins, sanitary engineer, concludes that generally speaking “it is unwise to dilute sewage with storm water and to befoul storm water with sewage in the attempt to remove both by the same underground channel.” Gregory has expressed the opinion that if sewage is to be discharged into a body without treatment the combined system will offer the simplest and cheapest solution of the problem.

Among the principal objections to the combined system when the sewage is treated are the increase it causes in the volume of liquid which necessarily requires a larger plant and expenditure, the changes it causes in the character of the sewage which complicates operation of the plant, and the frequency with which it causes the flow of sewage to exceed the maximum of the plant, thereby making it necessary to discharge untreated sewage into the stream. With a combined system all kinds of trade wastes must be run through the disposal plant, whether they are offensive or not; automatic devices, which should be avoided whenever possible, are necessary between the combined and intercepting sewers to limit the amount of flow; a greater amount of grit is deposited at the disposal works unless in the separate system the first wash of the street is intercepted. The New York State Board of Health advocates the separate system.

In constructing, extending or reconstructing a sewerage system it is well to bear in mind that even though a city has not at present a disposal plant, the time will come in all probability when increased population will compel the treatment of its sewage by some process. It may, therefore, be more economical eventually to make present plans so that when disposal does come the sewerage system will make possible the most economical operation of the disposal works. Gregory’s conclusion as recently expressed in an address is that “other things being equal, especially as more and more attention is being given to sewage disposal, the separate system seems to offer greater advantages.”

All engineers advocate good ventilation for sewers and gradients that will develop self-cleansing velocities, so as to reduce gas trouble and to deliver the sewage as fresh as possible to the disposal works. The best practise, according to reports of the State Boards of Health, show that these velocities should be not less than two feet per second in separate systems and two and one-half feet in combined systems. In some instances where it has been necessary to reduce the gradients because of the expense of obtaining steeper ones, a velocity of one foot per second has been found to be satisfactory; but in such instances sewers must be well constructed and flushed. Most trade wastes require a higher velocity to prevent deposits.