(3) Connect radio bonding to coil front ground terminal. Tighten nut securely.
(4) Connect coil to timer wire terminal to coil rear terminal screw. Connect wire shielding to coil rear ground terminal. Tighten nut securely.
(5) Swing air cleaner and bracket assembly back in place and install two bolts, lock washers, and nuts securing bracket to frame clamps. Tighten nuts securely.
(6) Connect battery negative ground wire to frame connection.
(7) Pass front cylinder high‐tension wire under tank, secure in cable clip at upper engine frame mounting, and attach cable end (radio noise suppressor) to front spark plug. Attach rear high‐tension cable end (radio noise suppressor) to rear spark plug.
(8) Check wiring connections ([fig. 48]) and test coil by engine starting.
Section XIX
GENERATING SYSTEM
| Paragraph | |
|---|---|
| Description | [90] |
| Clean commutator | [91] |
| Armature bearing special lubrication | [92] |
| Remove generator | [93] |
| Install generator | [94] |
| Cut‐out relay | [95] |