The case is noticeable because no evidence of high stress was apparent. The author saw nothing to suggest sinking of the central pier, the effect of which, within limits, would be to further reduce the stress as calculated; but it is quite possible some slight settlement had occurred; this, as the spans were so small, would have a sensible effect. While too much reliance should not, it is clear, be placed upon any estimated result about which there is a lingering doubt, it should be remarked that, as it would be necessary the pier should sink 3⁄16 of an inch, for each ton of reduced stress, it is not probable that the results quoted are in excess to any material degree; they are, indeed, more probably low, as no notice has been taken of impact.
Though cast-iron girders for railway under-bridges are now prohibited in this country for new works, there are still uses to which they may be applied, and it may be well to insist that girders of this material should be fairly loaded, the weight being brought upon them in such a way that there shall be no serious secondary stress, such as arises when wide flanges are made to carry concentrated loads; the author has, indeed, met with no instance of a cast-iron girder breaking down under a load fairly applied. Preference is now given to steel or wrought iron for columns; while this is often quite justifiable, there remain many cases in which nothing better need be desired for this purpose than good cast iron, provided only that the column be loaded in a suitable manner—i.e., axially, and that the arrangement and details of the super-structure are such that there shall be no cross-breaking efforts, or rocking of the column due to temperature or other causes; unless, indeed, such cross-breaking or rocking is definitely taken into account in designing the work. The same care observed in the detailing of cast-iron work that is not infrequently taken in the design of structures made of rolled sections would, in suitable cases, the author has no doubt, yield results just as reliable in practice, with the advantage of greater resistance to rust, and a reduced cost in maintenance.
Good cast iron is, in fact, when used with discretion, a most excellent material, popular predjudice notwithstanding. The oldest metallic bridge in this country at the present moment is of that metal.
The one chief respect in which cast iron is at a disadvantage compared with wrought iron or steel is that it does not give premonitory warning of failure—it remains intact, or it breaks. The indications of weakness, which may be read by an experienced inspector of other metallic bridges, are in a great measure absent. There is also an objection which may exist, but is to be avoided by good design and care in the foundry—viz., internal stress due to unequal cooling. In extreme cases this may lead to fracture before the work has left the maker’s hands, but it can only occur by neglect of ordinary precautions.
Figs. 82 and 83.
In a case which has already been referred to in the chapter on “[Deformations],” [page 80], an outer rib of a cast-iron arch fractured near the crown after fifty-four years’ use. Owing to the nature of the design, and the fact that the near abutment had closed in slightly, bringing the linear arch of necessity near the lower edges of the arch segment in question, it was possible to estimate, with a probability of truth, the extreme fibre stress (tensile) due to the load forces, at the upper edge where fracture commenced. The result was very far from explaining the occurrence of the break, but an examination of the details shown in [Figs. 82 and 83] will make it apparent that, in addition to the tensile stress, as calculated, there was probably a severe initial stress of the same character due to irregular cooling in the foundry half a century before. The sum of these stresses, it is suggested, placed this particular casting in a critical condition, such that operations in the construction of a new bridge adjacent either by producing a small further settlement of the foundations, of which the author saw no evidence, or, as is more probable, the attachment of a rope to this rib for the purpose of keeping a barge in position, which certainly did occur, gave the arch rib just such an additional strain as to result in the break shown, though no one of these causes acting singly would have been sufficient to induce fracture. The inner ribs were of a much less objectionable section.